Advanced Measurement and Monitoring for Smart Power Grids

Published: 2021-06-23 08:15:05
essay essay

Category: Ecology, Physics

Type of paper: Essay

This essay has been submitted by a student. This is not an example of the work written by our professional essay writers.

Hey! We can write a custom essay for you.

All possible types of assignments. Written by academics

GET MY ESSAY
Electric power networks around the world are being modified to smart power grids (SPGs) by integrating advanced monitoring and control methods. Wide Area Monitoring Systems based on the new data acquisition technology of Phasor Measurement Units has become an integral part of smart power systems. Phasor Measurement Unit (PMU) enables monitoring of transmission system conditions over large areas in view of detecting and further counteracting instabilities in grid. Advanced monitoring for transmission and distribution, essentially requires new measurement technologies. Phasor measurement units (PMUs) belong to that category. Current, voltage and frequency measurements are taken by PMUs at selected locations in the power system and stored in a phasor data concentrator (PDC) in hierarchical structure. The measured quantities are time-synchronised via Global Positioning System (GPS) receivers.
PMUs facilitate accurate monitoring of grid dynamics in real time. From the data obtained from PMUs, one can analyze sequence of events that have contributed to the catastrophic behavior of power system. A power system should work in a sinusoidal steady-state, characterized by a nominal frequency of either 50 or 60 Hz and thus the concept of phasor directly applies. The synchrophasor estimation is based on the same idea underlying the phasor, with the phase-angle calculated using Co-ordinated Universal Time (UTC) as a time reference. Therefore, it allows having a unique reference for all the sinusoidal signals to be measured in a wide or global area. Two synchrophasors, calculated at different points in a network, can be easily compared because they are related to common instants, because the time dissemination relies on satellite systems. Various research works are being carried out in analysis of PMU data.The fault in power system cannot be completely avoided. The longer it takes to identify and repair a fault, more harm may result in the electrical power system, especially in periods of peak loads, which could lead to the collapse of the system, causing the power outage to extend for a longer period and larger parts of the electrical network. It is essential to detect fault, its type and localise it. Incorporating PMU for this purpose is an area of ongoing research. The conventional methods used for detecting, classifying and localizing the fault are impedance measurement-based method and travelling wave method. PMUs are being increasingly used for detecting faults on transmission lines.
PMU are placed at optimal location in the transmission test system. A fault detection method is proposed using positive and zero sequence voltage measurements obtained from PMUs. This method can distinguish between faults and other disturbances/changes occurring in power systems. Once the fault is detected it is important to identify the type of fault. For this purpose a Support Vector Machine (SVM) has been proposed. The advantage of this method is that the input to SVM is measurements from PMU at generator bus alone. The structure of this paper is as follows. Section II explains the proposed fault detection method. The proposed SVM used for identifying the type of faults is explained in Section III. In Section IV, the proposed fault detection and classification algorithms are tested and validated on IEEE 14 bus system and results are discussed.

Warning! This essay is not original. Get 100% unique essay within 45 seconds!

GET UNIQUE ESSAY

We can write your paper just for 11.99$

i want to copy...

This essay has been submitted by a student and contain not unique content

People also read